About this project

Each student was told to choose unique chamber dimensions and unique materials for the chamber part and lid part. They should then find the percentage of yield their chamber and lid parts experience based on max von Mises stress on each part from the linear static load analysis. The inner surfaces were not loaded, or loaded with a pressure of 0. The outer surfaces were loaded with 1 atmosphere pressure. Default mesh setting.